Canalyzer

SCPI Commands :

INITiate:GPRF:MEASurement<Instance>:CANalyzer
STOP:GPRF:MEASurement<Instance>:CANalyzer
ABORt:GPRF:MEASurement<Instance>:CANalyzer
class CanalyzerCls[source]

Canalyzer commands group definition. 5 total commands, 1 Subgroups, 3 group commands

abort(opc_timeout_ms: int = -1) None[source]
# SCPI: ABORt:GPRF:MEASurement<Instance>:CANalyzer
driver.gprf.measurement.canalyzer.abort()


    INTRO_CMD_HELP: Starts, stops or aborts the measurement:

    - INITiate... starts or restarts the measurement. The measurement enters the RUN state.
    - STOP... halts the measurement immediately. The measurement enters the RDY state. Measurement results are kept. The resources remain allocated to the measurement.
    - ABORt... halts the measurement immediately. The measurement enters the OFF state. All measurement values are set to NAV. Allocated resources are released.

Use FETCh…STATe? to query the current measurement state.

param opc_timeout_ms:

Maximum time to wait in milliseconds, valid only for this call.

initiate(opc_timeout_ms: int = -1) None[source]
# SCPI: INITiate:GPRF:MEASurement<Instance>:CANalyzer
driver.gprf.measurement.canalyzer.initiate()


    INTRO_CMD_HELP: Starts, stops or aborts the measurement:

    - INITiate... starts or restarts the measurement. The measurement enters the RUN state.
    - STOP... halts the measurement immediately. The measurement enters the RDY state. Measurement results are kept. The resources remain allocated to the measurement.
    - ABORt... halts the measurement immediately. The measurement enters the OFF state. All measurement values are set to NAV. Allocated resources are released.

Use FETCh…STATe? to query the current measurement state.

param opc_timeout_ms:

Maximum time to wait in milliseconds, valid only for this call.

stop(opc_timeout_ms: int = -1) None[source]
# SCPI: STOP:GPRF:MEASurement<Instance>:CANalyzer
driver.gprf.measurement.canalyzer.stop()


    INTRO_CMD_HELP: Starts, stops or aborts the measurement:

    - INITiate... starts or restarts the measurement. The measurement enters the RUN state.
    - STOP... halts the measurement immediately. The measurement enters the RDY state. Measurement results are kept. The resources remain allocated to the measurement.
    - ABORt... halts the measurement immediately. The measurement enters the OFF state. All measurement values are set to NAV. Allocated resources are released.

Use FETCh…STATe? to query the current measurement state.

param opc_timeout_ms:

Maximum time to wait in milliseconds, valid only for this call.

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.gprf.measurement.canalyzer.clone()

Subgroups